RTCO=0, RTCPS=000, RTIE=0, RTCLKS=00, DMAE=0, RTIF=0
RTC Status and Control Register
RESERVED | no description available |
RTCO | Real-Time Counter Output 0 (0): Real-time counter output disabled. 1 (1): Real-time counter output enabled. |
DMAE | DMA Enable 0 (0): DMA request is disabled. Software polling needed. 1 (1): DMA request is enabled. |
RTIE | Real-Time Interrupt Enable 0 (0): Real-time interrupt requests are disabled. Use software polling. 1 (1): Real-time interrupt requests are enabled. |
RTIF | Real-Time Interrupt Flag 0 (0): RTC counter has not reached the value in the RTC modulo register. 1 (1): RTC counter has reached the value in the RTC modulo register. |
RTCPS | Real-Time Clock Prescaler Select 0 (000): Off 1 (001): If RTCLKS = x0, it is 1; if RTCLKS = x1, it is 128. 2 (010): If RTCLKS = x0, it is 2; if RTCLKS = x1, it is 256. 3 (011): If RTCLKS = x0, it is 4; if RTCLKS = x1, it is 512. 4 (100): If RTCLKS = x0, it is 8; if RTCLKS = x1, it is 1024. 5 (101): If RTCLKS = x0, it is 16; if RTCLKS = x1, it is 2048. 6 (110): If RTCLKS = x0, it is 32; if RTCLKS = x1, it is 100. 7 (111): If RTCLKS = x0, it is 64; if RTCLKS = x1, it is 1000. |
RESERVED | no description available |
RTCLKS | Real-Time Clock Source Select 0 (00): External clock source. 1 (01): Real-time clock source is 1 kHz. 2 (10): Internal clock. 3 (11): Bus clock. |
RESERVED | no description available |